Plastic Filter Backflush

plastik filtre back flush STF

Maximum
Performance in Filtering

There is no need to disassemble and clean the filter inner assembly to remove contaminants between the disks.

Since the filter is cleaned at 100% rate, irrigation continues without interruption while the system is running, thus ensuring efficient irrigation.

minion STF

Extra pure, extra clean irrigation system

STF

Helix System

Technical Specifications

Since the filter is cleaned at a rate of 100% while the system is running, irrigation continues uninterruptedly, thus providing efficient irrigation in waters with high pollutant content.

Since the filter cleaning time is short (10-20 seconds), the amount of water discharged during backwashing is very low.


Since the filter is cleaned 100%, the pressure loss in the system remains at a minimum level, preventing unnecessary energy costs.

plastik filtre back flush detay STF

Technical Data

D
(inch)
Code Connection
Type
Flow Rate
(m³)
Filtering
Surface
(cm²)
D
(mm)
D1
(mm)
H
(mm)
H1
(mm)
K
(mm)
T
(inch)
Weight
(kg)
Box
Dimensions
(W-D-H)
200-20 Y-Y-Y 25 1470 59 205 755 481 311 ¾" 9,5 76-36-27
2” 200-21 W-Y-W 25 1470 61 205 755 481 311 ¾" 9,5 76-36-27
200-22 W-W-Y 25 1470 61 205 755 481 311 ¾" 9,5 76-36-27
250-20 Y-Y-Y 30 1470 74 205 750 481 337 ¾" 10,0 76-36-27
2½” 250-21 W-Y-W 30 1470 76 205 750 481 337 ¾" 10,0 76-36-27
250-22 W-W-Y 30 1470 76 205 750 481 337 ¾" 10,0 76-36-27
300-20 Y-Y-Y 35 1470 87 205 765 481 340 ¾" 9,9 76-36-27
3” 300-21 W-Y-W 35 1470 89 205 765 481 340 ¾" 9,9 76-36-27
300-22 W-W-Y 35 1470 89 205 765 481 340 ¾" 9,9 76-36-27

Packaging Dimensions

hatici ebat STF
baglantitipi 1 1 STF
backflush 2 1 STF

Head Loss Table

grafik 3 STF

Material Properties

Body construction

PA 6

Max working pressure

8 Bar

Min working temperature

0 °C

Max working temperature

60 °C

Filtering

130 Micron

Inner set

Disk